The EN-FAB Steam Generator is a "once
through" forced circulation type. The
unit may be designed to supply wet, saturated or superheated steam discharge conditions. Pressure ratings will be supplied to
customer's specifications and are normally furnished in 1000, 1500, or 2500 PSIG working
pressure. The horizontal design is utilized for
easier transportation, field installation and repair, use of either gas or liquid
fuels, and elimination of vertical flow and entrained liquid fallback problems associated
with vertical type heaters. The horizontal serpentine straight tube
design simplifies tube and refractory repair if required as compared to helical wound or
vertical type installations. Drainage of the heater for non-operating periods in freezing
weather is simplified in the single tube serpentine design. 1. Feedwater Pump and Prime Mover The feedwater
pump is normally a positive displacement pump to provide the necessary feedwater pressure
and flow rate required for the generator. 2. Feedwater Preheater This is
normally a double pipe hair pin type heat exchanger used to raise the feedwater
temperature above the flue gas dew point to prevent condensation of water in the flue gas
and the resulting acid corrosion and deposits. 3. Radiant Section The radiant
section is cylindrical with horizontal tubes transposed around the radiant section for
equalized heat pick up. The tubes are supported with high alloy tube supports and are free
to expand with temperature changes. The radiant section also provides large furnace volume
for flexibility in combustion fuel and firing changes. The heat transfer surface in the
radiant section normally picks up about 60% to 65% of the overall heat transfer duty. The
refractory lined wall provides for reflective heat transfer to the tubes and insulation to
reduce heat loss through the chamber wall. 4. Convective Section The
convection section is fabricated from both bare and extended surface tubes. Flue gases
from the radiant section enters the convective section flowing across the bare or shock
tubes first and then across the extended surface tubes. The convective section normally
picks up 35% of 40%, or more, of the overall heat transfer duty. These convective sections are designed to give the desired
efficiencies. Mechanically they are designed for easy tube replacement and maintenance.
Side covers may be supplied with lay down doors for cleaning if desired. 5. Burner Burners may
be supplied for natural gas, butane, propane, or liquid fuels. Liquid fuels include crude oil. Heavy viscous oils
need preheating to provide a viscosity at the burner of 100 to 150 SSU's at the burner
nozzle. 6. Controls The feedwater
flow rate is controlled by the generator discharge pressure. The burner firing rate is
controlled by a metered flow rate signal. This allows the generator to be adjusted to give
the desired steam discharge quality. Standard and optional safety limit devices allow
unattended operation of the Generator. Certain limits are standard with annunciator lights
to indicate reason of shutdown. Other limits are optional along with additional
annunciator devices.